  Datasheet File OCR Text:
 Snap/Clip-Lock Environmentally Sealed - Circular
Engineering Quick Reference Selection Guide
2 Position Plug Receptacle
4 Position Plug
5 Position
Receptacle
Contact Arrangement
1 2 2 1
Contact Cannon
2 1 5 4 3 3 4
2 1 5
Inline Features Clip Lock
Feed Thru
Inline
PCB
Inline
Clip Lock
Clip Lock
Snap Lock
Snap Lock
Specifications
CS-216
CS-216
CS-216
CS-206
CS-206
Plug
086-0066-000 w/Wedgelock 086-0058-000 Standard
086-0058-000 Standard
Contact Cannon
098532-0000 (5 A) 098532-001 (13 A)
098532-0000 (5 A) 098532-001 (13 A)
Receptacle
086-0061-000 w/Wedgelock
083-0242-000
Contact Cannon
098531-0000 (5 A) 098531-0001 (13 A)
098530-0000 (5 A) 098530-0001 (13 A)
Terminals
See page 14
See page 14
Contact Cannon
See page 14
See page 14
How to Order
SLC
Series Prefix Size/Configuration Connector Type Contact Termination Material/Finish Modifier Mechanical Modifier
5
T
13
0
0
Series Prefix SLC - Snap-Lock Circular Size/Configuration 5-5 Cavity Housing 8-8 Cavity Housing 10-10 Cavity Housing 15-15 Cavity Housing
Contact Termination 5-5A 13 - 13 A Material/Finish Modifier 0 -Standard Assembly (Silicone Elastomer) 1 -Fluorosilicone Elastomer
Mechanical Modifier Connector Type 0 -Standard Assembly P - Plug, In-line (Cable-to-Cable)* R - Receptacle, In-line (Cable-to-Cable) T - Receptacle, Snap-thru B - Receptacle, PCB *Note: In-line Plug mates with all 3 receptacle types (In-line, Snap-thru, and PCB.)
Dimensions shown in mm Specifications and dimensions subject to change
4
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Engineering Quick Reference Selection Guide
Plug 8 Position Receptacle 10 Position Receptacle
3 2 10 9 6 8 7 6 7 8 7 5 5 9 10 1 1 10 15 9 8 14 6 6 8 9 7 2 11
Receptacle 15 Position
4
Plug
Plug
3 4
3 12 4 13 5 5 14
12 15
3 11 2 10 1
13
4
1 7 6 5 8
2 3 4 3 4
2 8 5 6
1 7 1
2
PCB Snap Lock (Double) CS-210
Inline Snap Lock (Double) CS-210
Snap-thru Snap Lock (Double) CS-210
PCB Snap Lock (Double) CS-206
Inline Snap Lock (Double) CS-206
Snap-thru Snap Lock (Double) CS-210
Snap-thru Snap Lock (Double) CS-210
098532-0010
098532-0008
098532-0010
098532-0002 (5 A) 098532-0002 (5 A) 098532-0002 (5 A) 098532-0003 (13 A) 098532-0003 (13 A) 098532-0003 (13 A)
086-0060-000
-
-
098533-0010
098531-0002 (5 A) 098530-0002 (5 A) 098531-0003 (13 A) 098530-0003 (13 A)
098533-0002 098533-0003
086-0059-000
See page 14
See page 14
See page 14
See page 14
See page 14
See page 14
See page 14
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
5
Snap/Clip-Lock Environmentally Sealed - Circular
Cannon SLC/SLC-T/CLC
The Snap Lock Environmental Series is environmentally sealed connector created for printed circuit board, black box, cable-to-cable or bulkhead applications. When your under-the-hood requirements call for tough performance, the SLC "snaps" into a tightly sealed connection that can withstand heat, shock and vibration. The connector is designed to preserve the integrity of the solid state package, while protecting against contaminants - even when unmated. Gold, tin/lead plated stamped contacts add durability. A rugged, thermoplastic receptacle body maximizes performance by withstanding temperature variances from -40C to +150C (material rating). The SLC series is available in 2, 5, 8, 10, 15 contact cavity configurations. It can also be adapted to robotics assembly. Should you requirement demand higher density configurations, consult Customer Service.
Product Features and Benefits
* Superior environmental sealing * Material rating: -40C to +150C continuous operation at rated current * Available in sizes 2, 5, 8, 10, 15 contacts * Crimp stamped gold, tin/lead plated contacts * Hand insertable/removable contacts * Current rating 5 A and 13 A versions * Low millivolt drop * Low contact resistance * Small footprint on P.C. board and low profile * Adaptable to robotics assembly * Latch with tactile and audible feedback * Increases durability and provides for minimum installation * Low installed cost * Requires less PCB space
Performance Specifications
Contact Resistance Insulation Resistance Current Rating Dielectric Withstanding Voltage Applicable Cannon Specification Material Rating Operating Temperature Crimp Contacts Wire Size Wire Insulation Sealing Range Contact Insertion Contact Extraction Contact Retention Wire Strip Length 10m maximum 20M minimum (USCAR) 5 A signal continuous at 150C all contacts, 2 position 13 A power continuous at 150C all contacts, 5 position and 10 position only 1000 Vrms AC at sea level SLC (CS-206) SLCT 5 & 10 (210) SLCT8 (216) SLCT 15 (206) -40C to +150C Semi-automatic or hand crimpable or fully automatic 20 - 16 AWG 1,98 (.078) to 3,30 (.130) dia. No tool required. Suitable for automation. Rear Removable 20 lbs. Minimum per contact 5,59 (.220) to 5,33 (.210)
Materials and Finishes
Connector Housing Contacts Finish High temperature thermoplastic Copper alloy Engaging area: Gold over nickel Crimp/P.C. tail area: Tin/lead over nickel - standard offering Tin/Lead over nickel - Option #2 all over High temperature silicone elastomer
Environmental Seal
Dimensions shown in mm Specifications and dimensions subject to change
6
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Contact Cavity Arrangements - Mating Face View
Plug
Cannon SLC/SLC-T/CLC
2 1 1 2 5 4 3 7 6
1 8 5
2 3 4
2 Way
5 Way
3 3 2 1 9 6 8 7 7 1 10 5 10 15 9 8 14 6 4 2 12 11 4 13 5
8 Way
10 Way
15 Way
Receptacle
2 3 2 1 4 5 1 3 4
2 8 5 6
1 7
2 Way
5 Way
8 Way
3 4 5 9 6 7 8 1 3 2 10 1 2 11 10 15 9 7 8 12 4 13 5 14 6
10 Way
15 Way
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
7
Snap/Clip-Lock Environmentally Sealed - Circular
Plug, In-line* (Cable-to-Cable) (Type P) SLC-5, SLC-10
Cannon SLC/SLC-T/CLC
Front-Face View 5 Cavity Housing
Side View Plug Assembly
Front-Face View 10 Cavity Housing
In-line Plug* (Mates with SLC types R, T, and B) Housing Size 5 5 10 10 Rating 5A 13 A 5A 13 A Part Number 098532-0011 098532-0001 098532-0002 098532-0003 Description SLC-5P5-00 SLC-5P13-00 SLC-10P5-00 SLC-10P13-00 A 27,81 (1.095) 26,80 (1.055) 34,92 (1.375) 34,04 (1.340) OB 18,03 (.710) 18,03 (.710) 24,15 (.990) 25,15 (.990)
*Contact lead assemblies are customer terminated and installed. See page 14, part numbers 110238-0488, 110238-2003.
Dimensions shown in mm Specifications and dimensions subject to change
8
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Receptacle, In-line* (Cable-to-Cable) (Type R) SLC-5, SLC-10
Cannon SLC/SLC-T/CLC
Front-Face View 5 Cavity Housing
Side View Receptacle Assembly
Front-Face View 10 Cavity Housing
In-line Receptacle* (Mates with SLC type P) Housing Size 5 5 10 10 Rating 5A 13 A 5A 13 A Part Number 098530-0000 098530-0001 098530-0002 098530-0003 Description SLC-5R5-00 SLC-5R13-00 SLC-10R5-00 SLC-10R13-00 A 24,13 (.950) 23,75 (.935) 31,24 (1.230) 30,86 (1.215) OB C Ref. 18,03 (.710) 24,38 (.960) 18,03 (.710) 24,38 (.960) 25,15 (.990) 31,62 (1.245) 25,15 (.990) 31.62 (1.245)
*Contact lead assemblies are customer terminated and installed. See page 16, part numbers 110238-0446, 110238-2004.
Square Flange
Snaps onto Type R and B connectors Materials and Finishes Material: Thermoplastic Color: Black
Housing Size 5 10
Part Number 066-9504.000 066-9504-001
A 23,37 (.920) 28,45 (1.120)
B Max. 31,24 (1.230) 36,32 (1.430)
OC 32,51 - 31,75 (1.280 - 1.250) 25,40 - 24,64 (1.000 - .970)
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
9
Snap/Clip-Lock Environmentally Sealed - Circular
Receptacle, Snap-thru* (Type T) SLC-5, SLC-10
Cannon SLC/SLC-T/CLC
Front-Face View 5 Position
Side View
Front-Face View 10 Position
Panel Section View
Panel Rear Face View
Snap-thru Receptacle* (Mates with SLC Type P) Housing Size 5 5 10 10 Rating 5A 13 A 5A 13 A Part Number 098533-0000 098533-0001 098533-0002 098533-0003 Description SLC-5T5-00 SLC-5T13-00 SLC-10T5-00 SLC-10T13-00 OA 37,21 (1.465) 36,96 (1.455) 47,62 (1.875) 47,37 (1.865) OB 24,13 (.950) 23,75 (.935) 31,24 (1.230) 30,86 (1.215) OC 25,60 (1.008) 25,48 (1.003) 35,05 (1.380) 34,92 (1.375) OD 15,62 (.615) 15,34 (.605) 20,19 (.795) 19,94 (.785)
*Contact lead assemblies are customer terminated and installed. See page 14, part numbers 110238-0446, 110238-2004.
Dimensions shown in mm Specifications and dimensions subject to change
10
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Receptacle, PCB* (Type B) SLC-5, SLC-10
Cannon SLC/SLC-T/CLC
Front-Face View 5 Cavity Housing
Side View In-Line Receptacle With PCB Contacts
Front-Face View 10 Cavity Housing
In-line Receptacle* (Mates with SLC Type P) Size 5 5 10 10 Rating Part Number 5A 13 A 5A 13 A 098531-0000 098531-0001 098531-0002 098531-0003 Description SLC-5B5-00 SLC-5B13-00 SLC-10B5-00 SLC-10B13-00 A 24,13 (.950) 23,75 (.935) 31,24 (1.230) 30,86 (1.215) OB 18,03 (.710) 18,03 (.710) 25,15 (.990) 25,15 (.990) C Ref. 24,38 (.960) 24,38 (.960) 31,62 (1.245) 31,62 (1.245)
*PCB Contacts are factory installed.
Recommended PCB Layout
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
11
Snap/Clip-Lock Environmentally Sealed - Circular
Receptacle, Snap-thru SLCT-8
Part No.: 098533-0010 (mates with 098532-0008) 48,26 (1.900)
Cannon SLC/SLC-T/CLC
27,56 (1.085)
Receptacle, Feed-thru CLC-2
Part No.: 086-0057-000 STRAIGHT PIPE THREAD SEALED INTERFACE 13,85 (.550)
fl
20,30 (.800)
SEALED INTERFACE
10,10 (.400) 22,90 (.900) PANEL MAX 44,00 (1.700)
4,45 (.175)
Note: In-line plug and receptacle available.
15,90 (.600)
Plug, Feed-thru CLC-2
Part No.: 086-0058-000 With Silicone Grommet Seal Part No.: 086-0058-001 With Silicone Grommet Seal Part No.: 086-0058-002 With Fluorosilicone Seal 32,26 (1.270)
23,00 (.900)
16,60 (.650)
13,20 (.520)
4,45 (.175)
A
B
19,30 (.760)
Right Angle CLC and CLC Y-Splice, please contact Product Management.
Dimensions shown in mm Specifications and dimensions subject to change
12
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Plug, Snap-thru SLC-15
Part Number: 086-0060-000
Cannon SLC/SLC-T/CLC
Receptacle, Snap-thru SLC-15
Part Number: 086-0059-000
Consult factory for alternate layouts.
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
13
Snap/Clip-Lock Environmentally Sealed - Circular
Contacts, Stamped, 5 and 13 Amp
Socket (use in plugs) Hooded Socket
Cannon SLC/SLC-T/CLC
Pin (use in receptacles)
Description 5A 13 A
Hooded Socket Socket Part Number 110238-1016 (030-2480-007)
Reeled Pin Part Number 110238-0446 (030-2464-007) 110238-2004 (030-2464-003)
Socket Part Number 110238-0488 (030-2480-000) 110238-2003 (030-2480-003)
Number of Contacts 4,500 4,000
Accessories
Sealing Plugs Connector Clip
Material: Thermoplastic, Color: Natural Part Number: 225-0093-000 +125C Rating
Material: Thermoplastic, Color: Natural Part Number: 225-0093-000 +125C Rating Mounting Hardware for use on In-line Receptacle (Cable-to-Cable) (Type R) Fits O6,35 (.250) hole x 0,51 (.020) thick panel.
Dimensions shown in mm Specifications and dimensions subject to change
14
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Extraction Tool
Contact Extraction Tool Part Number: 274-7068-001 Tip Part Number: 323-9519-000
Cannon SLC/SLC-T/CLC
A Standard CET - SLE/SLC is available for extraction of the individual crimp contacts. Insertion tool is not required.
Insertion / Extraction Instructions for Crimp Contacts
Insertion Tool No insertion tool is required. The contact is easily snapped in from the rear of the connector manually.
1. Move to the rear of the connector so that the contact cavities can be identified.
2. Insert a crimp terminated assembly into a selected cavity.
3. Continue the forward movement until and audible snap can be felt and heard. Slight pull in the opposite direction will confirm complete insertion.
Extraction
1. Open the CET - SLC Extraction tool and place it over the insulation of the wire.
2. Using a straight motion forward, insert the tool along the wire until it bottoms against the connector. (Do not use a screwing motion damage will result.)
3. While the extraction tool is in place, simply pull the wire/contact assembly out.
4. Remove the extraction tool. Extraction is complete.
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
15
Snap/Clip-Lock Environmentally Sealed - Circular
Hand Crimp Tool Operation
Hand Crimp Tool - CCT - SLC / SLE Part Number: 995-0002-232
Cannon SLC/SLC-T/CLC
The CCT-SLC/SLE hand crimp tool is designed to crimp individual SLC/SLE contacts on wire sizes 16, 18, and 20 AWG. Each cycle is ratchet-controlled (The tool must be completely closed before it can be reopened) to assure a satisfactory crimp each time. Over and under crimps are eliminated. This tool is for use when the requirement is for low to moderate volume quantities, and for on-site applications where semiautomatic tools cannot be practically used.
1. Cycle the CCT - SLE / SLC hand tool to the open position.
2. While pressing upward on the locator spring, insert the contact with tails upward completely into the locator.
3. When correctly positioned the contact should be located beyond flush with the edge of the CCT - SLE / SLC and positioned in the concave polished split level crimp.
4. Partially (usually the first click) Cycle the hand tool assuring that the upward thrusting tails of the contact has started engaging with the top jaw of the tool. (There is a slight tendency for the contact to roll out of vertical alignment.)
5. Insert the pre-stripped wire into the crimp area of the contact and completely cycle the tool.
6. While pressing upward on the locator spring withdraw the crimp termination.
Wire Stripping
7. The result will be a perfect termination.
8. Note that there are no unterminated wire strands, and that some strand ends can be seen at the forward edge of the crimp. Also note the insulation is gripped by the smaller secondary crimp. Distortion is at a minimum, both axially and laterally - no sharp edges.
Tolerance Low High
5 and 13 A Contact B A 5,33 (.210) 2,41 (.095) 5,59 (.220) 3,30 (.130)
Dimensions shown in mm Specifications and dimensions subject to change
16
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Lease Automatic Tooling - North America*
ABT-607 Pneumatic Crimper The ABT-607 is a pneumatic powered and controlled machine. It is designed for customers with moderate volume. This machine is designed to semiautomatically crimp stamped and formed contacts onto pre-stripped stranded or single conductor electrical wire. This machine will accommodate size 34 thru 12 AWG wire and is actuated by the use of a foot pedal.
Cannon SLC/SLC-T/CLC
Machine Crimp Rate: 800 per hour Power Requirements: Pneumatic = 100 psi, 2 cu. ft. per min.
ABT-500 UCCD The ABT-500 Universal Cannon Crimp Die, is a flywheel driven, electronically controlled machine that is designed to semi-automatically crimp stamped and formed contacts on stranded or single conductor, prestripped wire. This machine will accommodate size 34 thru 12 WG wire. The machine is actuated by the use of a foot pedal. Machine Crimp Rate: 1300 per hour Power Requirements: Electrical = 115VAC, 60Hz, 20A
ABT-620 UCCS The ABT-620 Universal Cannon Crimper/Stripper is a pneumatic powered, microprocessor controlled machine. It is designed to semi-automatically strip insulation from stranded or single conductor electrical wire and attach a stamped and formed contact by crimping. The machine will accommodate 34 thru 12 AWG wire. Primary application of the machine is the termination of jacketed cable where the individual leads cannot be stripped by fully automated equipment. The ABT-620 UCCS operates automatically upon insertion of a wire or it can be switched over to foot pedal operation if desired. Machine Crimp Rate: 1200+ per hour Power Requirements: Electrical = 115VAC, 60Hz, 20A Pneumatic = 80 psi, 3 cu. ft. per min.
* For other geographical regions, contact Cannon for details.
Dimensions shown in mm Specifications and dimensions subject to change
www.ittcannon.com
17
Snap/Clip-Lock Environmentally Sealed - Circular
Crimp Pot Cross Section
Cannon SLC/SLC-T/CLC
D CRIMP WIDTH C CRIMP HEIGHT
Crimp Height and Width
CRIMP POT CROSS SECTION
The wire crimp heights listed are only reference and valid for the correspondingly listed wire size, wire plating and wire stranding. The wire crimp tensile values must be used to assure the performance of crimped contacts. For wire crimp information not listed in this table, please contact Cannon.
Wire Gauge (AWG) 18 D Ref. C* D Ref. C* Signal (5A) .064* .082 .056* .080 Power (13A) .066* .082 .062* .080 * Hand Tools are .002 and machines are .001 16
20 C* .054* .058* D Ref. .080 .080
Insulation Height and Width Wire Gauge (AWG) 18 Width Height Height Max Max** Max Signal (5A) .110 .115** .105 Power (13A) .110 .115** .105 ** Measurements are taken without crimping wire insulation. 16 20 Width Max** .110** .110** Height Max .105 .105 Width Max** .110** .110**
Crimp Tensile Strength
Wire Trim Dimension
(.220 - .210)
(.130 - .095)
Wire Size (AWG) Tensile Min (lbs)
16 35 lbs.
18 25 lbs.
20 20lbs.
Dimensions shown in mm Specifications and dimensions subject to change
18
www.ittcannon.com
Snap/Clip-Lock Environmentally Sealed - Circular
Test Parameters
Cannon SLC/SLC-T/CLC
SLC Products are designed to meet Cannon specifications CS-206, CS-210, and CS-216. Items of most general interest to users are designers are listed below. Test Description
Environmental Sealing
Reference Paragraph
3.2.3.5 3.2.3.6 3.2.3.7 3.2.3.8 3.2.3.9 3.2.3.2 3.2.2.1
Requirements
Sand and Dust MIL-STD-202 Method 110 Test Condition A 5% salt spray 96 hours 10 cycles of 24 hours, 90-98% humidity Steam Cleaning/Pressure Wash 95C, 375 Cycles 750 PSIG Solvent Resistance/Immersion (see 3.2.3.9) Thermal Shock 100 Cycles -40C to +150C 3C The minimum tensile load required to separate the wire from the contact, either by pulling the wire out of the crimp joint or by breaking the wire within the crimp joint shall not be less than the applicable limits as specified. Wire breakage or contact damage not due to crimping at less than tensile loads shall not constitute a failure. Wire Size AWG Crimp Tensile Strength, Pounds Minimum 16 35 18 25 20 20 Mated and wired connectors shall exhibit an insulation resistance greater than 100 megohms between all contacts. This limit shall apply after exposure to each environment including salt solution immersion. Tests shall be performed at 100 VDC 10%. Wired and mated connectors shall show no evidence of breakdown between adjacent contacts when tested at 1000 VDC 5%. Connectors shall meet this requirement after exposure to each environment. Current leakage shall be less than 1.0 milliamp. The low level contact resistance of mated contacts shall be less than 10 milliohms when measured across the contacts and crimp joints. The test current shall be a maximum of 100 milliamps with an open circuit test voltage of 20 millivolts maximum. Connectors shall be subjected to three shocks in each direction applied along the three mutually perpendicular axes of the connector test specimen for a total of 12 shocks. Each shock shall consist of a terminal peak sawtooth pulse with a peak value of 100 g's and a duration of 6 milliseconds. Connectors shall be subjected to random vibration in accordance with MIL-STD-1344, Method 2005.1, test condition VI for 20 hours along each of the following three axes: Direction Grms Radial axis of connector (Y) 10.2 Longitudinal axis of connector (Z) 10.2 Electrical continuity of the connectors shall be monitored during the last 20 minutes sweep in each axis with a test current of 100 milliamps or less and a test voltage less than 2VDC. Electrical discontinuities in excess of 10 microseconds shall be cause of failure. Connectors shall be subjected to 25 cycles of mating and unmating at room temperature. Following this test there shall be no evidence of damage to the contacts, contact plating, connector housing or seals which may prove detrimental to reliable performance of the connector. Contacts shall not be displaced greater than 0.030 inches from the connector body when a force of 10 pounds is applied. When this test follows maintenance again the same contacts shall be tested. Consist of subjecting each wired receptacle to 5 cycles of removal and reinsertion of 20% of the contacts or a minimum of 5 per connector with approved tooling. The maximum force required to mate the plug and receptacle shall be 10 pounds. The maximum force required to separate the plug and receptacle shall be 5 pounds. The rate of travel shall be one inch per minute. Connectors shall be subjected to the following fluids at the temperature and length of time specified. Following the fluid dip or immersion, the connectors shall be immersed to a depth of 2 to 12 inches in a 5% salt-water solution for 24 hours at room temperature. At the completion of the salt-water immersion test, while still immersed, the connectors shall meet the insulation resistance requirement specified herein. Fluid Method Temperature No. 2 Diesel Fluid Immersion (2) 140F Methyl Alcohol Dip (1) Room Temperature Antifreeze - Prestone Immersion (2) 180F - 50% Water/50% Immersion (2) 180F Ethylene Glycol Degreaser - Gunk Dip (1) Room Temperature - Mineral Spirits Dip (1) Room Temperature Paint (Oil Base) Immersion (2) Room Temperature Lubricating Oil Immersion (2) 200F (SAE 10 W40) Dip (1) Room Temperature Brake Fluid (Delco Supreme) Room Temperature Dip (1) Transmission Fluid fully submerged and pressurized @ 7 psi. (Dextron) (1) Dip: Connectors shall withstand a one second dip and a three minute air dry for a total of 80 cycles. (2) Immersion: Connectors shall withstand immersion for one hour. Connectors shall be subjected to a temperature of 150C 3C for a period of 1000 hours. At the end of the temperature soak period and after removal from the chamber, the connectors shall meet the insulation resistance and dielectric withstanding voltage requirements specified herein. Connectors shall be operated at rated current throughout the duration of the temperature life test. Upon removal from the chamber at the conclusion of the test, the connectors shall show no visual signs of damage, which may be detrimental to the performance of the connector. Connectors shall be subjected to 100 thermal cycles from -40C to +150C. One cycle shall consist of the transitions from room temperature to -40C to +150C, and from 150C to room temperature. One cycle shall be accomplished in a three-hour period with a minimum stabilization period of 15 minutes at each temperature extreme. The chamber temperature transition rate shall be a minimum of 1.30C per minute and a maximum of 6.00C per minute.
Contact Crimp Tensile Strength
Insulation Resistance Dielectric Withstanding Voltage Low Level Contact Resistance Mechanical Shock
3.2.1.1
3.2.1.2
3.2.1.4
3.2.3.3
Vibration
3.2.3.4
Durability
3.2.2.6
Contact
3.2.2.2
Maintenance Aging Mating and Separating Force Solvent Resistance Immersion
3.2.2.3
3.2.2.4
3.2.2.9
Temperature Life
3.2.3.1
Thermal Cycling
3.2.3.2
Specifications and dimensions subject to change
www.ittcannon.com
19


▲Up To Search▲   

 
Price & Availability of SLC8P500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X